What should I do if the fixed concrete mixing plant is tripped? How to solve?
Fixed concrete mixing station as a stable production equipment, some faults in the process of long-term use are difficult to avoid, how to resolve the trip of the concrete mixing station:
When the fault occurs, first pay attention to the moment when the trip is the moment, there is an A symbol current table on the dashboard, and the operating current of the whole machine will be displayed.
If the current reaches 150 or more and more than 200 trips, it should be that the natural overheat protection of the clicks is too large. Check that the skin has a short ablation, and the belt speed is not slowed, or Check if the mixing station has entered the big piece of part. To eliminate the above questions, if you can't resolve, please contact the electrician or manufacturers in time for processing repairs.
There is no more than 150 trips, exclude tripping, and no problem, check the overload protector (thermal electrical appliance), normally adjusted numerical range, as a three-phase motor, should be twice the power of the motor, if hot The preservation is only connected to the Star Triangle to start a line, and the numerical range that should be adjusted can be the same as the motor power. For example, the WDZ600 mixer motor power is 75KW, then if the value is adjusted, it should be adjusted to 150-160 between, If the position of the mixer heat warping is a line that is started with the motor star triangle, then it should be not less than 75.